Riester’s RVS-100 is an advanced
vital signs monitor which offers pulse oximetry, blood pressure and
temperature measurements. The device has ‘Monitor‘, ‘Spot-Check‘
and ‘Triage‘ profile options and a high performance touchscreen.
The RVS - 100 can communicate
through a wired or wireless connection to the hospital’s EMR, according
to the HL7 standard. The highly flexible, modular design offers many
configurations and settings to suit the needs of hospitals, clinics and
private practices, as well as long-term care settings.
Product Details
-
3 measurement modes (Monitor,
Spot-check, Triage)
-
High-sensitivity 8”
TFT colour touch screen with self-explanatory user interface and
integrated help- function
-
Displays SYS, DIA, MAP, Pulse, Temp,
Plethysmogram
-
Clinical grade NIBP* including
averaging mode
-
Programmable NIBP averaging mode (2-5
readings)
-
Riester, Masimo* or Nellcor* Oximax
SpO2
-
Predictive Thermometer (Filac 3000)
-
Connectivity with the EMR - follows
the HL7 standard
-
LAN Connectivity as standard
-
Programmable alarms (audible,
visible) with 3 priority levels
-
Supports nurse call RJ11 port
-
Available as wall, desk and floor
model
-
Can be expanded to wall diagnostic
station
-
Internal memory for 5,000
measurements
-
Lithium-ion battery with up to 17
hours ON time (*includes neonate mode)
Specifications
Monitor
-
Power Supply: 100 - 240 V AC, 50/60
Hz
-
Battery
-
Lithium-Ion battery,
rechargeable, 10.8 V DC, 6,600 mAh
-
Charging time to 100%: 6
hours,
-
Operating time approx. 11
hours (new and fully charged battery at 25° C ambient temperature
with connected SpO2, Temp, and NIBP on AUTO mode (15 minutes
interval))
-
Low battery indicator
-
Charging battery indicator
-
Dimensions Monitor: L x H x W: 303 x
230 x 110 mm (11.93 x 9.06 x 4.33 in)
-
Weight: 3.60 kg (7.94 lb) including
temp module, printer
-
Dimensions Basket: L x H x W: 270 x
225 x 200 mm (10.63 x 8.86 x 7.88 in)
Alarm
-
Visible LEDs (Yellow, Red, Blue,
Green, Orange)
-
Audible Speaker
-
Gives audible alarm, QRS tone
-
Supports Pitch Tone and multi-level
volume
-
Alarm tones meet the requirement of
IEC 60601-1-8.
-
Alarm Pressure: 45 dB to 85 dB test
distance is 1 meter from the tone.
Ports
-
1 x AC power inlet
-
1 x standard RJ45 interfaces.100
BASE-TX, IEEE 802.3
-
4 x USB ports
-
1 x Equipotential grounding point
-
1 x RJ11 connector for nurse call
-
DC out port 15V/1.2 A Clinical-grade
NIBP (non-invasive blood pressure)
Clinical-grade NIBP
(non-invasive blood pressure)
-
Measuring method: automatic
oscillometric
-
Measurement range
-
Adult SYS 30 - 270 mmHg,
DIA 10 - 220 mmHg, MAP 20 - 235 mmHg
-
Pediatric SYS 30 - 235
mmHg, DIA 10 - 220 mmHg, MAP 20 - 225 mmHg
-
Neonate SYS 30 - 135 mmHg,
DIA 10 - 110 mmHg, MAP 20 -125 mmHg
-
Cuff pressure range: 0 - 280 mmHg
-
Resolution: 1 mmHg
-
Pressure accuracy
-
Pulse rate range: 40 - 240 bpm
-
Pulse rate accuracy: 1 bpm
-
Initial inflation pressure
-
Adult 160 mmHg, Pediatric
130 mmHg, Neonate 75 mmHg
-
Double overpressure
protection (hardware and software)
-
Adult 297 ± 3 mmHg,
Pediatric 252 ± 3 mmHg , Neonate 147 ± 3 mmHg
Alarm range
-
SYS 0 - 300 mmHg
-
DIA 0 - 300 mmHg
-
MAP 0 - 300 mmHg
SpO2
-
Measurement range: 0 - 100%
-
Resolution: 1%
-
Accuracy
-
±2% (70 to 100%)
-
±3% (40% to 69%)
-
Unspecified (0% to 39%)
-
Alarm range: 0 - 100%
-
Average time: 4 sec, 8 sec, 16 sec
-
Pulse rate
Predictive thermometer
-
Oral ( Quick Mode )
-
Oral ( Standard Mode ): 6-10 seconds
-
Axillary Mode: 8-12 seconds
-
Rectal Mode: 10-14 seconds
-
Direct Mode (all sites): 60-120
seconds
-
Measurement accuracy: 35.5°C
- 42°C (95.9°F - 107.6°F)
-
Direct Mode (all sites): ±0.1°C (±0.2°F)
-
Standard Prediction Mode (all sites):
±0.1°C (±0.2°F)
-
Quick Prediction Mode (oral only): ±0.3°C (±0.5°F)
|
Models Available :
-
1960-RRXPE RVS-100,
NIBP(Riester)+ SpO2(Riester) + printer
-
1960-RRXPG RVS-100,
NIBP(Riester)+ SpO2(Riester) + printer
-
1960-RRXXE RVS-100,
NIBP(Riester)+ SpO2(Riester)
-
1960-RRBXE
RVS-100,NIBP(Riester)+SpO2(Riester) + Pred. Temp (oral / axillary)
-
1960-RRBPE
RVS-100,NIBP(Riester)+SpO2(Riester) + Pred. Temp + Printer
-
1960-RNXXE RVS-100, NIBP
(Riester)+ SpO2 (Nellcor)
-
1960-RNBXE RVS-100,
NIBP(Riester)+SpO2(Nellcor) + Pred. Temp
-
1960-RNBPE
RVS-100,NIBP(Riester)+SpO2(Nellcor) + Pred. Temp
-
1960-RMXXE RVS-100,NIBP
(Riester)+SpO2 (Masimo)
-
1960-RMBXE RVS-100, NIBP
(Riester)+ SpO2 (Masimo) + Pred. Temp
-
1960-RMBPE RVS-100, NIBP
(Riester)+ SpO2 (Masimo) + Pred. Temp + Printer
|